Ceramic Feedthru.

TM 5-3610-220-14
C4
Page 1-11.  After figure 1-11, add figure 1-11.1, Copying
1-4. Administrative Storage.
Camera schematic wiring diagram.
For instructions on the administrative storage of equipment
Page 2-14. After paragraph 2-36,add paragraph 2-36.1 as
refer to TM 740-90-1.
follows:
Page 1-2. Add figure 1-1.1 and 1-2.1.
2-36.1. Lamp Control Switch (Model 1969M).
Page 16, Paragraph 18.
After subparagraph i add
A two-position toggle switch is located on standard in the
subparagraph j as follows:
gallery. It is used to operate the lamps either manually or
automatically with the light exposure unit. The two positions
j. Pulsed Xenon Lighting System. The Lumax Model
operate as follows:
L1500L Pulsed Xenon Lighting System is comprised for four
1500 watt light units each with a 24 ft cable and one PS6-4UL
a. Manual position (toggle switch in up position).
power supply.  The four light units are mounted on the
Allows operator to turn camera lamps on and off manually
copying camera, two on each side of the camera, and are
using the camera manual switches.
supported by the camera arm assembly.
b. Automatic  position  (toggle  switch  in  down
The Pulsed Xenon Light can be positioned to the correct
position). Allows operator to turn camera lamps on and off
distance and angle by adjusting the camera arm assembly
automatically through the light exposure unit.
and the light mounting yoke.
Page 4-17. In Chapter 4, after Section VII, add Section VII.1
Page 1-6.  After paragraph 1-3j add fig. 1-7.1, Copying
as follows:
Camera, three quarter view from copyboard end (Model
1969M).
Section VII.1. MAINTENANCE OF THE PULSED XENON
LIGHTING SYSTEM (MODEL 1969M)
4-31.1. Description.
b. Removal.
(1)  Rotate light unit by loosening yoke knob (1,
On all 1969M models of the copying camera the copyboard is
fig. 4-7.1) on light head; turn light head so that glass front is
illuminated by four Pulsed Xenon light units which give a
facing up. Tighten yoke knob.
maximum area of uniform lighting. The pulsed xenon lights
(1, fig. 4-6.1) are mounted on a mounting rod (3) which is
(2)  Remove screws (2) from four glass clips (3)
fastened to the camera arm assembly (2). Each light unit is
and remove glass cover (4). Lift glass out.
connected to the power supply assembly.
(3)  Remove lamp tube (5) by first disconnecting
The Pulsed Xenon Light can be positioned to the correct
AMP connectors at each end of tube. Gently pry tube from
distance and angle by adjusting the camera arm assembly
retainer clips (6) and remove.
and the light mounting yoke.
CAUTION
4-31.2. Xenon Pulsed Lamp.
Avoid touching lamp tube as much as
possible. Grease or dirt on surface of
a. Description. The Xenon pulsed lamp is a xenon gas
tube decreases the life span of the
filled 12-inch glass tube which is illuminated by a pulsed
lamp.
Wear white gloves when
electrical current. Each lamp, Luma Model T12L1500, is 1500
handling lamp.
watts. Both ends of the glass tube lamp are fitted with metal
caps.  The lamp clips into retainer clips in the xenon light
CAUTION
housing.
Do not twist tube or it will break.