Page Title: Section III. OPERATION UNDER USUAL CONDITIONS
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Table 2-1. Preventive Maintenance Checks and Services -- Continued
Up
TM-11-7025-232-10 Line Printer RP-309/MYQ-4A (NSN-7010-01-177-0646) Manual
Next
POWER ON/POWER OFF LINE PRINTER

TM 11-7025-232-10
Section III. OPERATION UNDER USUAL CONDITIONS
2-4. ASSEMBLY AND PREPARATION FOR USE
See your system manual for information on location of the ac power source. Before
y o u insert the ac power plug into the power source, check that the ON/OFF power
switch is in the OFF position.
Make sure these items are installed before operation.
·
Ribbon
cartridge
·
Character
band
·
Paper
· VFU tape
2-5. INITIAL ADJUSTMENTS, DAILY CHECKS, AND SELF-TEST
P e r f o r m the following initial adjustments, daily checks, and self-test before start
up.
WARNING
Top edges of character band are sharp. Avoid contact.
a . Press 6/8 LINES switch for desired lines per inch.
b.
I n s t a l l if necessary.
Check paper supply.
Make paper TOP OF FORM and character alinement settings.
c.
d.
C h e c k that sprockets are locked into position.
e.
Check that VFU tape is mounted and read by tape reader.
f .  C h e c k that printer is free from ribbon and paper dust. If necessary, lift
top cover and clean printer with vacuum.
9.  C h e c k i n k i n g c o n d i t i o n o f r i b b o n . R u n s e l f - t e s t . I f p r i n t i s l i g h t , a d j u s t
P H A S E or COPIES control or install new ribbon cartridge. If print is still too
l i g h t tell your supervisor maintenance is required.
2-6. OPERATING PROCEDURES
The operating procedures which follow enable you to prepare the line printer for
o p e r a t i o n ; operate, remove from operation, and place in standby condition or
shutdown status.

Privacy Statement - Press Release - Copyright Information. - Contact Us