Click here to make tpub.com your Home Page

Page Title: Direct and General Support Water System Troubleshooting Chart
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Direct and General Support Electrical System Troubleshooting Chart
Up
TM-11-6780-225-35 Darkroom Photographic Transportable ES-82A Manual
Next
Direct and General Support Heater and Film and Print Drying Cabinets Troubleshooting Chart

TM 11-6780-225-35
Item
Trouble symptom
Probable trouble
Corrective measure
No.
14
Refrigerator does not operate
a
Refrigerator control set too low,
a
Set refrigerator control to higher
set to OFF, or defective
position, or replace refrigerator
control as required.
b
Defective power cord-
b  Replace power cord.
c
Defective refrigerator.
c  Replace refrigerator.
15
No power to control panel of film and
a
CB7 set to OFF
a  Set CB7 to ON.
print drier, and space heater
b
CB7 resets to OFF when set to
b  Replace CB7, or repair film and
ON
print drier, and space heater
installation as required.
16
No power to circuit 8 outlets
a
CB8 in OFF position or defective
a. Set CB8 to ON or replace as
required.
b
Defective outlet-
b  Replace outlet.
17
No power to control unit
CB9 in OFF position or defective
Set CB9 to ON position or replace
as required.
18
No power to water pump
a
CB10 in OFF position or
a  Set CB10 to ON position or
defective
replace as required.
b
Water pump switch set to OFF or
b  Set water pump to ON or replace
defective
as required.
19
No power to incandescent lights
a.
CB11 in OFF position or
a  Set CB11 to ON position or
defective
replace as required.
b
Incandescent light switch in OFF
b  Set switch to ON position or
position or defective
replace as required.
3-6.
Direct and General Support Water System Troubleshooting Chart
Item
Trouble symptom
Probable trouble
Corrective measure
No.
1
No cold water when faucet (S7) is
a
No main water being supplied to
a
Check tank level, make certain tank
turned on, and no pressure read
inlet from water storage tank
inlet is not blocked.
on pressure indicators
b.
Drain valve (D7) is open
b
Close valve (D7).
c
Main strainer is completely
c
Clean or replace strainer.
clogged.
Figure 3-1. Water heater, schematic diagram.
3-3

Privacy Statement - Press Release - Copyright Information. - Contact Us