Organizational Monthly Preventive Maintenance Checks and Services Chart
Up
TM-11-6720-248-12 Camera Set Still Picture KS-19A4 AND KS-19B Manual
Next
Figure 5-1. Triggering circuit, exploded view.

TM 11-6720-248-12
(para 4-7) and the organizational troubleshooting chart
does not restore normal equipment performance,
troubleshooting  is  required  by  higher  category
maintenance personnel.  Note on the repair tag the
corrective measures taken.
5-7. Organizational Troubleshooting
a. General. Before using the troubleshooting chart,
The troubleshooting chart (b below) is provided as an aid
examine the repair tag to see whether the trouble has
in localizing trouble in the camera set. It supplements
been  sectionalized.
If  there  has  been  no
the operator troubleshooting chart (para 4-7). Only those
sectionalization, perform the procedures outlined in the
corrective
measures
which
the
organizational
operator troubleshooting chart (para 4-7).
maintenance personnel can apply are given.  If the
suggested measure
b. Organizational Troubleshooting Chart.
Item No.
Trouble symptom
Probable trouble
Checks and corrective measures
a. Defective batteries.
a. Replace strobe assembly batteries
1
Neon indicator (fig. 3-4) fails
to glow within 15 seconds
b. Defective neon indicator.
b. Refer equipment to higher cate-
after strobe assemblies are
flashed (battery operation).
gory of maintenance for repair.
a. Broken or loose wiring in flash or
a. Remove junction box cover and
2
One or both strobe assemblies
do not flash when shutter
shutter cord.
check continuity of electrical
is tripped.
circuits. Use low ohms scale of
Multimeter AN/URM-105, and
repair break in circuit.
b. Defective flash synchronization
b. Disconnect shutter cord from lens
switch in lens and shutter as-
and shutter assembly. Short cen-
sembly.
ter conductor to outer shield of
shutter cord. If strobe assem-
blies flash, shutter synchroniza-
tion switch is defective; refer
equipment to higher category
maintenance for repair.
c. Defective strobe assembly.
c. Refer equipment to higher cate-
gory maintenance for repair.
d. Defective battery in triggering cir-
d. Replace battery in triggering cir-
cuit.
a. Compress the two battery compartment clips
5-8. Replacement of Triggering Circuit Battery
and withdraw the old battery tray.
b. Install a new battery tray and press in until the
Replace the triggering circuit battery as follows:
plastic clips engage with the strobe assembly housing.
a. Loosen the two screws that secure the junction
box cover.
b. Remove the junction box cover.
5-10.
Replacement  of  Spreader  Rollers  and
c. Note the polarity position of the battery and
Bushings
remove the battery from the clips.
d. Install the replacement battery in the position
Replace the spreader rollers and bushings in the camera
noted in c above.
back cover assembly (when required) as follows:
e. Install the junction box cover and secure it by
a. Open the back cover assembly (para 3-3d).
b. Gently spring the roller assembly release latch
tightening the screws loosened in a above.
outward until the roller assembly is released.
c. Swing the roller assembly away from the back
5-9. Replacement of Battery Tray
cover assembly.
Install a new battery tray in the strobe assembly (when
required) as follows: