Figure 3-4. Body, exploded view (part 3 of 6).
Up
TM-11-6720-242-35 Camera Still Picture KA-60C Manual
Next
Figure 3-4 . Body, exploded view (part 4 of 6).

TM 11-6720-242-35
69
Bearing (MP152-153)
56
Gear (MP162)
70
Gear ('MP158)
57
Pin (MP163)
71
Gear (.MPi56)
58
Shim (MP167)
72
Screw (H44-46)
59
Bearing (MP148-149)
73
Pin (MP161)
60
Cam and gear shaft assembly (MiP150)
74
Pin (MPW1)
61
Puck (MP329)
75
Cam (MP157)
62
Screw (H202-203)
76
Adapter (MP151)
63
Shim (MP364)
77
Pin (MP813)
94
Retaining ring (MP337)
78
Shaft (MP166)
65
Cover (MP177)
198
Housing (MP204)
66
Screw (H93-94)
67
Spacer (MP168) 68 Pin (MP163)
Figure 3-4(3))--Continued.
3-29. Reassembly and Installation of
(9) Wiring data for connector 2J1 of the
Interconnecting Board Assembly
camera control.
Connector
AWG
Insulation tubing
a. Reassembly (fig. 3-12).
and is
unwire size
(1) Reassemble electrical connectors 2J1 (7),
designation
AWG size
Length (in.)
2J2 (11), and 2J3 (9) as follows. Assembly of  the
J1-A....................... No. 20.................... 18 ............... 7/16
J1-C ...................... No. 20.................... 18 ............... 7/16
remaining parts is obvious.
J1-E....................... No. 20.................... 18 ............... 7/16
(2) To facilitate their connection to the board
J1-G ...................... No. 20.................... 18 ............... 7/16
J1-J ....................... No. 20.................... 18 ............... 7/16
assembly, it is recommended that new wires be cut in 8-
J1-L ....................... No. 20.................... 18 ............... 7/16
inch lengths.
J1-N ...................... No. 20.................... 18 ............... 7/16
J1-R- ..................... No. 20.................... 18 ............... 7/16
(3) Subparagraphs (9), 10), and (11) be-low,
J1-T....................... No. 20.................... 18 ............... 7/16
list pin designations, wire sizes, and the size and length
J1-V....................... No. 20.................... 18 ............... 7/16
of  insulation  tubing  for  the  respective  electrical
J1-Y....................... No. 20.................... 18 ............... 7/16
J1-Z....................... No. 20.................... 18 ............... 7/16
connectors. All wires are bus type.
J1a ........................ No. 20.................... 18 ............... 7/16
(4) Insert a wire of designated AWG size into
J1-e ....................... No. 20.................... 18 ............... 7/16
J1-g ....................... No. 20.................... 18 ............... 7/16
a contact and after checking the proper seating of the
J1-h ....................... No. 20.................... 18 ............... 7/16
wire, through the inspection hole in the contact, secure
J1-j ........................ No. 20.................... 18 ............... 7/16
J1-n ....................... No. 16.................... 14 ............... 7/16
the assembly with crimping tool MS3191-1.
J1-n ....................... No. 20.................... 18 ............... 7/16
(5) Insert the contact through the grommet
J1-p ....................... No. 20.................... 18 ............... 7/16
J1-r........................ No. 16.................... 14 ............... 7/16
from the rear of the connector, using inserting tool
* Pin letters that are not listed are spares.
MS24256A20. A slight click will be felt when the contact
Use bare bus wire In the AWG sizes designated.
is properly seated in the connector. When wiring
(10) Wiring data for connector 2J2 of the
connector 2J1, note that a different size wire is
camera control.
designated for contacts m and .
Connector
AWG
Insulation tubing
(6) When connector is completely wired, cut
and is
unwire size
designation
AWG size
Length (in.)
the insulation tubing to size and slide tubing all the way
J1-A....................... No. 20.................... 18 ............... 7/16
to the connector on each wire. Pass the entire bundle of
J2-A....................... No. 20.................... 18 ............... 5/16
wires from each connector through the appropriate
J2C........................ No. 20.................... 18 ............... 5/'16
J2-E....................... N9. 20.................... 18 ............... 5/16
nutplate (8, 10, or 12).
J2-G ...................... No. 20.................... 18 ............... 5/16
(7) See that the side without components, of
J24 ........................ No. 20.................... 18 ............... 5/16
J2-L ....................... No. 20.................... 18 ............... 5/16
the interconnecting board, (13) faces the connector.
J2-N- ..................... No. 20.................... 18 ............... 5/16
Being sure that the wires pass through the nutplate,
J2-P- ..................... No. 20.................... 18 ............... 5/16
J2-S....................... No. 20.................... 18 ............... 5/16
insert the wires from the connector through the assigned
J2-T....................... No. 20.................... 18 ............... 5/16
connection points of the interconnecting board. Maintain
J2-U ...................... No. 20.................... 18 ............... 5/16
J2-V....................... No. 20.................... 18 ............... 5/16
a dimension of 0.020 + 0.005 inch between the face of
J2-W ..................... No. 20.................... 18 ............... 5/16
the mounting flange of a connector and the face of two
J2-X....................... No. 20.................... 18 ............... 5/16
J2-Y....................... No. 20.................... 18 ............... 5/16
posts (1) and one post (4). Solder the wires to the
J2-Z....................... No. 20.................... 18 ............... 5/16
interconnecting board connections and cut off the
J2-b ....................... No. 20.................... 18 ............... 5/16
excess lengths of wire.
J2 .......................... No. 20.................... 18 ............... 5/16
* Pin letters that are not listed are spares.
(8) Repeat (4) through (7) above to wire all
U0e bare bus wire in the AWG sizes designated.
three connectors as designated in (9), (10), and (11)
below.
3-21