Page Title: Figure 3-10. Electronic mounting block adjustments.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Figure 3-9. Baseblock assembly adjustment diagram.
Up
TM-11-6720-239-35 Camera Set Still Pictures KS-101(A) Manual
Next
Electronic Mounting Block Color Code/Value Table

TM 11-6720-239-35
Figure 3-10. Electronic mounting block adjustments.
erture opening. The end of the closing blade
(g) Must R1 (6) as necessary to obtain
required reading.
spring should rest on the retaining pin.
b. Electronic Mounting Block Assembly Adjust-
CAUTION
ment.
This adjustment affects all shutter
speeds. To insure accurate shutter per-
(1) General. To adjust the electronic mount-
formance, after the R1 adjustment has
ing block assembly, first make all shutter electri-
been made, a complete shutter assembly
cal connections.
operational test ( para. 4-4) must be per-
(2) Adjust top potentiometer R1 on the elec-
formed.
tronic mounting block (fig. 3-10) as follows:
(3) Adjust the bottom potentiometer (R3) on
(a) Disconnect the white battery clip from
the electronic mounting block (fig. 3-10) as fol-
battery B1 (fig. 3-10).
lows :
(b) Connect the negative (-) lead of a
multimeter to the white battery clip.
(a) Connect the negative (-) lead of a
multimeter to the negative (-) terminal of bat-
(c) Connect the positive (+) lead of the
multimeter to the positive (+) terminal of the
tery B1.
battery.
(b) Connect the positive (+) lead of the
multimeter to the wiper arm of R3.
(d) Cock the shutter and set electronic
mounting block face down on the workbench.
(c) Cock and trip the shutter. The meter
(e) Set the multimeter to a scale higher
should indicate 0.75 vdc or more.
than 20 ma DC.
(d) If the meter indicates less than 0.75
vdc, replace photocell V1 with a photocell from
(f) Trip the shutter and read the meter.
The reading should be 20 ± 1 MA.
the next lower color group.