TM 10-3610-203-14 Table 3-2.  Troubleshooting Malfunction Test or Inspection Corrective Action SHELTER SYSTEM AND COMPONENTS 1.  NO ELECTRICAL POWER TO SHELTER SYSTEM Step 1.  Inspect to me that the generator is operating properly. Start  the  generator  set  in  accordance  with  the  applicable  Department  of  the  Army  Technical Manual. Step 2.  Check that main power cable is correctly connected at main power receptacle. WARNING Do not perform any electrical maintenance or make any electrical connection or disconnection at the main power receptacle while the generator set engine is running. Connect  the  primary  power  cable  to  the  input  power  receptacle  located  near  the  door  of  the shelter. The cable connector and the receptacles are keyed to ensure proper connection. Step 3.  Check to see if the main power cable leads are properly connected at generator. The leads of the power cable are color coded as follows: Phase A - black - Pin 1 Phase B - red - Pin 2 Phase C - green (marked with blue band) - Pin 3 Neutral - white - Pin 4 Step 4.  Inspect to see if main breaker is in the on position Position applicable circuit breaker to on. 2.  NO ELECTRICAL POWER AT EQUIPMENT RECEPTACLES Inspect to see if main circuit breaker is in the on position. Position applicable circuit breaker to on. 3.  DUPLICATING MACHINE NOT PRODUCING GOOD COPY Check for incorrect impression-to-blanket cylinders adjustment. Adjust cylinder pressure in accordance with commercial manual instructions. 3-5

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing