TM-10-3610-203-14 Press Shelter Unit of the Transportable Special Warfare Printing Plant Manual
Next
Section II.  OPERATION OF AUXILIARY EQUIPMENT

TM 10-3610-203-14 d. Air Conditioner.  Refer to TM 5-4120-226-15 for the necessary air conditioner operating instructions. e. Fire Extinguisher.  The monobromotrifluoromethane type fire extinguisher is bracket mounted on the rear wall of the shelter just left of the shelter door.  It is generally suitable for use on all types of fires, with the exception of fires involving LOX (liquid oxygen) generating equipment.  The fire extinguisher is furnished with a disposable type cylinder. To operate the fire extinguisher, perform the following operations: (1) Remove the fire extinguisher from its storage bracket. (2) Break the seal by pulling the safety pin from the handle. (3) Point the horn at base of the flame. (4) Depress trigger for discharge and direct the stream at the base of the fire. (5) Replace used cylinder with a new cylinder immediately after using. f. Blackout  Warning.    A  blackout  warning  system  consisting  of  an  external  pushbutton  switch  and  an  internal buzzer is provided to alert shelter personnel to extinguish all lights before the door is opened during blackout periods. The pushbutton switch is mounted on the outside wall of the shelter to the left of the door.  The buzzer is mounted on the rear of the shelter above the main power service box.  A chain mounted blackout lockpin is installed on the door center latch plate on the interior rear left wall.  When the door is closed and latched, the pin passes through a hole in the locking mechanism to prevent the door from being inadvertently opened during a blackout. g. Shelter  Door  Filter.    An  air  filter  is  located  near  the  center  of  the  shelter  door  and  incorporates  an  upward hinging weather cover over the filter opening on the door exterior. h. Telephone Binding Post.  Two external binding posts are located on the exterior rear shelter wall to the left of the door.  They are protected by a hinged weather cover and are provided to facilitate connection of a field telephone between the units of the special warfare printing plant. i. Level Indicator.  Two bubble-gage type level indicators are installed in the exterior shelter wall, one on the rear wall  and  one  on  the  left  wall.    During  operation,  the  shelter  should  be  as  level  as  possible  so  as  not  to  affect  the calibration of plant components. j. Main Power Service Box.  The main power service box mounted on the rear wall of the shelter to the right of the  door,  contains  the  circuit  breakers  which  control  electrical  power  to  the  shelter  components  and  afford  overload protection to these circuits.  The circuit breakers are switch-type components which also provide a convenient means of disconnecting power to all shelter circuits. k. Light and Switches.  Illumination of the shelter is provided by two rows of ceiling lights, controlled by two light switches on the rear wall of the shelter to the left of the door.  Each light fixture incorporates a ballast, a lamp starter and a fluorescent lamp tube.  Five light fixture assemblies are installed along the left and right ceiling. 2-4.  Stopping WARNING Do not perform any electrical maintenance or make any electrical connection or disconnection at the main power receptacle while the generator set engine is running. a. Shut down the generator set power source in accordance with the applicable Department of the Army Technical Manual. b. Position all circuit breakers in the main power service box to the right of the shelter door to off. c. Position all equipment and shelter power switches to the off or neutral position. d. Disconnect the main power cable from the generator power source. e. Disconnect the cable from the main power receptacle. f. Coil and correctly stow main power cable. 2-7

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing