Back Table 4-1. Organizational Preventive Maintenance Checks and Services - cont | Up TM-10-3610-202-14 Editorial and Photochemical Shelter Unit The Transportable Special Warfare Printing Plant Manual | Next Table 4-1. Organizational Preventive Maintenance Checks and Services - cont |
TM-10-3610-202-14
Table 4-1. Organizational Preventive Maintenance Checks and Services
Legend
W - Weekly
Q - Quarterly
A-Annually
H - Hours
M - Monthly
S - Semiannually
B - Biennially
MI - Miles
For Readiness
Interval
Reporting
Item
Item To Be
Equipment is Not
No.
W
M
Q
S
A
B
H
MI
Inspected
Procedures
Ready/Available If:
19
·
Shelter Door Filter
Inspect for cleanliness,
damage and proper installa-
tion. If necessary, clean
filter as follows:
Remove the filter by
pulling the foam material
from the frame.
Clean by washing in a soap
and water solution. Dry
thoroughly and spray with
coater (NSN 4130-00-860-
0042).
Install filter by inserting
foam material under
bottom lip of frame, then
tucking it under remaining
three lips of frame.
20
·
Ladder
Inspect for damage and
ensure that clamps are
properly attached and are
not damaged. If inspection
indicates that repair or
replacement of the ladder is
necessary, refer to para-
graph 4-53.
21
·
Level Indicator Gages Inspect the level gages for
secure mounting, broken or
cracked sight glass. if
inspection indicates that
replacement of the level
gages is necessary, refer
to paragraph 4-55.
22
·
Fluorescent Lamps
Inspect lamp for correct
illumination. If inspection
indicates that replacement
of the lamp is necessary,
refer to paragraph 4-57.
23
·
Lamp Switches
Inspect for proper operation,
loose connections and
excessive wear. Inspect
switch box cover for
security of mounting. If
inspection indicates that
replacement of a switch is
necessary, refer to para-
graph 4-59.
4-13
|