Section III.  TROUBLESHOOTING
Up
TM-10-3610-202-14 Editorial and Photochemical Shelter Unit The Transportable Special Warfare Printing Plant Manual
Next
Camera Lamp

TM 10-3610-202-14 Table 3-2.  Troubleshooting (Con't) MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 3.  PRINTING LAMP DOES NOT COME ON WHEN OPERATING PLATEMAKER.  I Step 1.  Inspect for failure of mercury vapor lamp Replace failed lamp as described in paragraph 3-9. 4.  LIGHT TABLE WILL NOT ILLUMINATE. Check for defective fluorescent tube Replace defective fluorescent tube as described in paragraph 3-9. 5.  CAMERA VACUUM COPYBOARD INOPERATIVE. Using foot pedal.  operate vacuum pump and check for leaks from vacuum hose extending from pump to underslide of copyboard. Disconnect defective hose at pump and copyboard and replace hose as described in paragraph 3-11. 6.  WATER SUPPLY IS COLD. Step 1.  Check to see if the immersion heater is plugged into wall receptacle Plug immersion heater into wall receptacle. Step 2.  Check to see if the proper circuit breaker In the main panel for the immersion heater Is in the or position. Position applicable circuit breaker to on. 7.  RELATIVE HUMIDITY WITHIN SHELTER BELOW 50. Check for closed humidifier water supply line valve at base of water tank. Open humidifier supply line valve. Section IV.  MAINTENANCE PROCEDURES 3-7.  General. Maintenance procedures applicable to the operator are, for the most part, limited to servicing and secondary type maintenance on the commercial equipment  which  forms  a  part  of  the  shelter  system. Many  of  these  servicing  and  maintenance  procedures are outlined in the commercial publications supplied with the  various  items  of  equipment.    This  section  contains those procedures not covered by commercial publications    or    procedures    deemed    to    be    operator responsibility. 3-8.  Platemaker Mercury Vapor Tube. Replace mercury vapor light tube as follows: a.    Position  PLATEMAKER  circuit  breaker  in  main power service box to off. b.    Pull   out   on   flip-top   frame   release   knob   and move   knob   down   to   lowest   position.      Place   flip-top frame to vertical position. c.  Remove the Allen setscrews and clamps from each  side  of  the  lamp  reflector  and  remove  the  glass shield. 3-7

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing