TM 10-1670-327-23&P
0006 00
ATTACH MAIN CLOSING LOOP TO MAIN PACK TRAY
1. Route the main closing loop (figure 13, item 1) under the main closing loop protective cover (figure
13, item 2) and through the grommet (figure 13, item 3).
2. Rotate the closing loop (figure 13, item 4) 90° insuring the loop opening is facing to the inside of the
pack tray (figure 13, item 5).
CAUTION
Do not attempt to tack through stiffener. Failure to heed caution will result in damage to
the stiffener.
3. Using a 12-inch length of one turn double tape lacing and tying (figure 13, item 6), tack both sides of
the closing loop protective cover (figure 13, item 7). Secure with a surgeons knot locking knot
trimming the ends to within 1-inch.
1
2
4
6
3
7
5
Figure 13. Routing the Main Closing Loop, Closing Loop Under The Protective Cover, Main Closing
Loop Through Grommet, and Tacking Both Sides.