Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: RATE THRESHOLD (NO FIRE) TEST - CONT
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
RATE THRESHOLD (ALL FIRE) TEST
Up
TM-10-1670-305-23P Automatic Ripcord Release AR2 Model 451 NSN 1670-01-369-7914 Test Chanber Assembly AR2 Model 452 NSN 1670-01-370-0752 Manual
Next
ACTUATION ALTITUDE TEST

TM 10-1670-305-23&P 0010 00-12 ELECTRONIC TEST CHAMBER ASSEMBLY, MODEL 453 0010  00 OPERATION UNDER USUAL CONDITIONS - CONT OPERATING PROCEDURE RATE THRESHOLD (NO FIRE) TEST - CONT 7.     The AR2 shall not actuate. 8.     Set AR2 JUMP/OFF switch to OFF. 9.     Repeat steps 2 through 8 using AR2 altitude dial setting of 10,500 feet, test chamber altitude setting of 12,500 feet, and same fall rate setting.  For this step, set AR2 JUMP/OFF switch to OFF when altitude reaches 9,500 feet. 10.  If no other tests are to be performed, follow shut down after testing procedure at end of this work package. ACTUATION ALTITUDE TEST 1.     Ensure CHAMBER VENTED indicator (16) and DISPLAYS LOCKED indicator (18) are extinguished. 2.     Set AR2 altitude dial to 3000 feet.  Close altitude chamber lid (2). 3.     Press and hold  HOLD DOWN TO SET switch (13); and set altitude to 5000 ± 100 feet. Release HOLD DOWN TO SET switch (13). 4.     Press and hold  HOLD DOWN TO SET switch (13); and set fall rate to 110 ± 10 ft/sec. Release HOLD DOWN TO SET switch (13). 5.     If ALTITUDE DWELL indicator (6) is not illuminated or flashing, press GO TO ALT AND DWELL switch (7).  Wait until ALTITUDE DWELL indicator (6) stops flashing. 6.     Set AR2 JUMP/OFF switch to JUMP.  Press FALL switch (9). 7.     Wait for AR2 to actuate and DISPLAYS LOCKED indicator (18) to illuminate. 8.     Observe ALTITUDE (FT MSL) display (20) and FALL RATE (FT/SEC) display (19). 9.     The AR2 must actuate within 300 feet of AR2 dial setting. 10.  Set AR2 JUMP/OFF switch to OFF.  Press HOLD DOWN TO COCK switch (10) and observe movement of piston rod to right until AR2 cocks. 11.  Repeat steps 1 through 10 using AR2 dial setting of 8000 feet, test chamber altitude setting of 10,000 feet, and same fall rate setting. 12.  Repeat steps 1 through 10 using AR2 altitude dial setting of 15,000 feet, test chamber altitude setting of 17,000 feet and same fall rate setting. The altitude actuation tolerance is ± 500 feet for this setting.

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing