Page Title: RATE THRESHOLD (ALL FIRE) TEST
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
AR2 FUNCTIONAL TESTS TABLE
Up
TM-10-1670-305-23P Automatic Ripcord Release AR2 Model 451 NSN 1670-01-369-7914 Test Chanber Assembly AR2 Model 452 NSN 1670-01-370-0752 Manual
Next
RATE THRESHOLD (NO FIRE) TEST - CONT

TM 10-1670-305-23&P 0010 00-11 ELECTRONIC TEST CHAMBER ASSEMBLY, MODEL 453 0010  00 OPERATION UNDER USUAL CONDITIONS OPERATING PROCEDURE RATE THRESHOLD (ALL FIRE) TEST 1.     Install AR2 in test chamber. 2.     After test chamber warm-up, ensure DISPLAYS LOCKED indicator (18) and CHAMBER VENTED indicator (16) are extinguished.  If not, press RESET DISPLAYS switch (17). 3.     Set AR2 altitude dial to 5500 feet.  Close altitude chamber lid (2). 4.     Press and hold  HOLD DOWN TO SET switch (13) and use SET ALTITUDE control (4) to set Test Chamber altitude to 7500 ± 100 feet. Release HOLD DOWN TO SET switch (13). 5.     Press and hold  HOLD DOWN TO SET switch (13) and use SET FALL RATE control (5) to set fall rate at 87.5 ± 0.5 ft/sec. Release HOLD DOWN TO SET switch (13). 6.     If ALTITUDE DWELL indicator (6) is not illuminated or flashing, press GO TO ALT AND DWELL switch (7).  Wait until ALTITUDE DWELL indicator (6) stops flashing. 7.     Set AR2 JUMP/OFF switch to JUMP.  Press FALL switch (9). 8.     The AR2 shall actuate within 300 feet of AR2 dial setting. 9.     Set AR2 JUMP/OFF switch to OFF, press HOLD DOWN TO COCK switch (10), and observe movement of piston rod to right until AR2 cocks. 10.  If required, repeat steps 2 through 9. 11.  If no other tests are to be performed, follow shut down after testing procedures at end of this work package. RATE THRESHOLD (NO FIRE) TEST 1.     Ensure DISPLAYS LOCKED and CHAMBER VENTED indicators (16, 18) are extinguished. If not, press RESET DISPLAYS switch (17). 2.     Set AR2 altitude dial to 5500 feet. Close altitude chamber lid (2). 3.     Press and hold  HOLD DOWN TO SET switch (13) and set Test Chamber altitude to 7500 ± 100 feet. Release HOLD DOWN TO SET switch (13). 4.     Press and hold  HOLD DOWN TO SET switch (13) and set fall rate at 62.5 ± 0.5 ft/sec. Release HOLD DOWN TO SET switch (13). 5.     If ALTITUDE DWELL indicator (6) is not illuminated or flashing, press GO TO ALT AND DWELL switch (7).  Wait until ALTITUDE DWELL indicator (6) stops flashing. 6.     Set AR2 JUMP/OFF switch to JUMP.  Press FALL switch (9).  Wait until the altitude as observed on the ALTITUDE (FT MSL) display (20) reaches 4500 feet.