TM 10-1670-305-23&P
0010 00-10
ELECTRONIC TEST CHAMBER ASSEMBLY, MODEL 453
0010 00
OPERATION UNDER USUAL CONDITIONS - CONT
OPERATING PROCEDURE
NOTE
Operating Procedures for the ELECTRONIC TEST CHAMBER ASSEMBLY,
MODEL 453 consist of evaluation testing of the AR2.
1. Verify that the JUMP/OFF switch is in OFF position, the storage cable and piston rod cap are
removed, and that AR2 is cocked.
WARNING
If there is any indication of a leak in the aneroid, remove the AR2 from service. A
leaking aneroid may cause a malfunction which may result in death of
parachutist.
2. Check the AR2 for aneroid leakage at ground level before testing (WP 0008).
NOTE
AR2 functional test requirements are summarized in table below.
AR2 FUNCTIONAL TESTS
TYPE OF TEST
AR2 DIAL
SETTING
RATE OF FALL
ALTITUDE
ACTUATION
TOLERANCE
Rate threshold
Verification:
Fire Test
5,500 ft
85/90 fps
± 300 ft
No Fire Test
5,500 ft
60/65 fps
No fire
No Fire Test
10,500 ft
60/65 fps
No fire
Altitude
Actuation
Verification:
Fire Test
3,000 ft
100/120 fps
± 300 ft
Fire Test
8,000 ft
100/120 fps
± 300 ft
Fire Test
15,000 ft
100/120 fps
± 500 ft
Fire Test
Required
Actuation
Altitude, MSL*
100/120 fps
± 300 ft or
± 500 ft
* See paragraph 13 of Actuation Altitude Test.
|