Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: FALL RATE TEST
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
ALTITUDE STABILITY TEST - CONT
Up
TM-10-1670-305-23P Automatic Ripcord Release AR2 Model 451 NSN 1670-01-369-7914 Test Chanber Assembly AR2 Model 452 NSN 1670-01-370-0752 Manual
Next
FALL RATE TEST - CONT

TM 10-1670-305-23&P 0010 00-5 TEST CHAMBER ASSEMBLY, MODEL 453 0010  00 OPERATION UNDER USUAL CONDITIONS FALL RATE TEST RANGE 1.     Obtain a timer (stop watch). 2.     Press and hold  HOLD DOWN TO SET switch (13), use SET ALTITUDE control (4) to set altitude to 3000 ± 100 feet as observed on ALTITUDE (FT MSL) display (20).  Release HOLD DOWN TO SET switch (13). 3.     Press and hold  HOLD DOWN TO SET switch (13); use SET FALL RATE control (5) to achieve 26 ± 1 ft/sec fall rate as observed on FALL RATE (FT/SEC) display (19).  Release HOLD DOWN TO SET switch (13). 4.     Press GO TO ALT AND DWELL switch (7). 5.     When ALTITUDE DWELL indicator (6) stops flashing, use altitude chamber switch lever (1) to set AR2 JUMP/OFF switch to JUMP. 6.     Press FALL switch (9).  Set AR2 JUMP/OFF switch to OFF. 7.     At first reading below 2000 feet start timer and record altitude.  At first reading below 1000 feet, stop timer and record altitude. 8.     Difference between two altitude readings divided by the time equals the fall rate.  Fall rate shall be less than 30 ft/sec. 9.     Repeat step 2 using 4000 ± 100 feet. 10.  Repeat step 3 using 225 ± 1 ft/sec. 11.  Press GO TO ALT AND DWELL switch (7). 12.  When ALTITUDE DWELL indicator (6) stops flashing set AR2 JUMP/OFF switch to JUMP. 13.  Press FALL switch (9); set AR2 JUMP/OFF switch to OFF. 14.  At first reading below 2000 feet start timer and record altitude.  At first reading below 1000 feet, stop timer and record altitude. 15.  Difference between two altitude readings divided by the time equals the fall rate.  Fall rate shall be greater than 200 ft/sec. 16.  Repeat steps 2 through 15 using a preset altitude of 27,000 feet for the 26 ft/sec test and 28,000 feet for the 225 ft/sec test. Determine the fall rate between 26,000 feet and 25,000 feet for both tests. 17.  If no other tests are to be performed, follow shut down after testing procedures at end of this work package.

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing