AR2 FUNCTIONAL TESTS TABLE
Up
TM-10-1670-305-23P Automatic Ripcord Release AR2 Model 451 NSN 1670-01-369-7914 Test Chanber Assembly AR2 Model 452 NSN 1670-01-370-0752 Manual
Next
TEST CHAMBER ASSEMBLY, MODEL 452 OPERATION UNDER USUAL CONDITIONS - CONT

TM 10-1670-305-23&P TEST CHAMBER ASSEMBLY, MODEL 452   0009  00 OPERATION UNDER USUAL CONDITIONS OPERATING PROCEDURE 12.  Rotate the altitude chamber switch lever (2) clockwise 180°.  This will move the AR2 JUMP/OFF switch to OFF position. 13.  Repeat steps 6 through 10. WARNING If malfunctions of the rate-of-fall mechanism occur, or if actuation altitude deviates from the dial setting by more than the prescribed tolerance, remove the AR2 from service. 14.  To complete the test for rate-of-fall mechanism verification: a.    Conduct a no-fire test using the above procedure.  Leave the altitude dial set at 5,500 feet and set the rate of fall between 60 and 65 ft/sec.  The rate of fall should be established between 6,000 and 5,000 feet.  Actuation of the AR2 should not occur at any altitude. b.    Conduct a second no-fire rate of fall test with the AR2 altitude dial set to 10,500 feet.  Set the rate of fall between 60 and 65 ft/sec.  The rate of fall should be established between 11,000 and 10,000 feet.  Actuation of the AR2 should not occur at any altitude. 15.  To conduct actuation altitude tests: a.    Set the AR2 dial to 3,000 feet.  Set the rate of fall between 100 and 120 ft/sec.  The rate of fall should be established between 3,500 and 2,500 feet.  Actuation of the AR2 should occur at 3,000 feet ± 300 feet. b.    Set the AR2 dial to 8,000 feet.  Set the rate of fall between 100 and 120 ft/sec.  The rate of fall should be established between 8,500 and 7,500 feet.  Actuation of the AR2 should occur at 8,000 ± 300 feet. c.    Set the AR2 dial to 15,000 feet.  Set the rate of fall between 100 and 120 ft/sec.  The rate of fall should be established between 15,500 and 14,500 feet.  Actuation of the AR2 should occur at 15,000 feet ± 500 feet. d.    Set the AR2 dial to the MSL altitude where actuation is required for a normal mission profile. Set the rate of fall between 100 and 120 ft/sec. The rate of fall should be established between 500 feet above and 500 feet below the dial setting. The altitude actuation tolerance is ± 300 feet for dial settings below 10,000 feet MSL and ± 500 feet for settings of 10,000 or above. CAUTION To protect altimeter from damage, do not press RAPID FALL DUMP switch at altitudes greater than 25,000 feet. 16.  Depress and hold the RAPID FALL DUMP switch (7) until the test chamber is dumped. 0009  00-9 Change 1