Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: TEST CHAMBER ASSEMBLY, MODEL 452 0009 00 OPERATION UNDER USUAL CONDITIONS
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
TEST CHAMBER ASSEMBLY, MODEL 452 OPERATION UNDER USUAL CONDITIONS – CONT
Up
TM-10-1670-305-23P Automatic Ripcord Release AR2 Model 451 NSN 1670-01-369-7914 Test Chanber Assembly AR2 Model 452 NSN 1670-01-370-0752 Manual
Next
TEST CHAMBER ASSEMBLY, MODEL 452 OPERATION UNDER USUAL CONDITIONS - CONT

TM 10-1670-305-23&P TEST CHAMBER ASSEMBLY, MODEL 452   0009  00 OPERATION UNDER USUAL CONDITIONS INITIAL ADJUSTMENT BEFORE USE 5.    Turn the PRESSURE CONTROL regulator (10) on the test chamber fully counterclockwise to its stop. NOTE If the test chamber will not maintain altitude, there is a leak in the pneumatic system.  Ensure that compression nuts are hand tight and that the altitude chamber gasket is not damaged.  DO NOT USE WRENCHES.  If the chamber still does not maintain altitude, send it back to depot for repair. 6.    Move the CLIMB/FALL/COCK switch (8) on the test chamber to FALL position.  Verify that the altitude reading remains at 6,500 feet or that it falls less than 100 feet in ten seconds. 7.    Move the CLIMB/FALL/COCK switch (8) to CLIMB. 8.    Turn the PRESSURE CONTROL regulator (10) on the test chamber clockwise to obtain 15 PSI on the PRESSURE GAGE (11). 9.    Move the CLIMB/FALL/COCK switch (8) on the test chamber to FALL and, using a stopwatch, record the time it takes for the altimeter to fall from 6,000 to 5,000 feet. 10.  Calculate the rate of fall in ft/sec by dividing 1,000 by the stopwatch time.  Using an erasable marker, soft pencil, or other suitable instrument, transfer the pressure value from the PRESSURE GAGE (11) and the rate of fall to the appropriate spaces on the FUNCTIONS decal (9) on the test chamber. 11.  Move the CLIMB/FALL/COCK switch (8) to CLIMB. 12.  Change the reading on the PRESSURE GAGE (11) to a higher or lower value as required. 13.  Repeat steps 9 through 12 as required to obtain rate of fall information within the desired range. CAUTION To protect altimeter from damage, do not press rapid fall dump switch at altitudes greater than 25,000 feet. 14.  Move CLIMB/FALL/COCK switch (8) to FALL, and increase pressure in altitude chamber to ambient by holding down on RAPID FALL DUMP switch (7). 15.  Position test chamber ON/OFF switch (5) to OFF. 16.  Open lid (1) of altitude chamber and remove AR2 (3). 17.  Prepare AR2 for storage or movement (WP 0023 00). 18.  Altimeter calibration.  If altimeter (4) calibration is required, refer to (WP 0021 00 for removal and replacement. 0009 00-5 Change 1

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing