![]() ![]() TM 11-6625-2781-14&P-2
Section I
Table 1-3. Test Equipment (cont'd)
Item
Minimum Specifications or Required Features
Suggested Model
Tunable RF Voltmeter
Bandwidth: 1 kHz
HP 8405A Vector
Frequency Range: 1-310 MHz
Voltmeter
Sensitivity: 10 mV to 1 V rms
Input Impedance: >0.1 megohms
Wave Analyzer
Frequency Range: 90-110 kHz
HP 310A Wave
Frequency Accuracy: ±2%
Analyzer
Bandwidth: 1000 Hz
Voltage Accuracy: +6% of full scale
Input Impedance: >10k
Sensitivity: <100 µV rms
Digital Voltmeter
Voltage Accuracy: + 0.2%
HP 3440A Digital
Voltage Range: 1-50 Vdc full scale
Voltmeter with
Input Impedance: 10 megohms
HP 3443A Plug-In
Ohmmeter
Resistance Ranges: 10 ohm to 10 megohms
HP 410C Volt-
Accuracy: +10% of reading
Ohm-Ammeter
Oscilloscope
Frequency Range: dc to 50 MHz
HP 180A w/ HP 1801A
Time Base: 1 µs/div to 10 ms/div
Vertical Amplifier, and
Time Base Accuracy: +3%
HP 1821A Horizontal
Dual Channel, Alternate Operation
Amplifier
Ac or dc coupling
External Sweep Mode
Voltage Accuracy
Sensitivity: 0.005 V/div
Table 1-4. Test Accessories
Item
Minimum Specifications or Required Features
Suggested Model
Service Kit
Contents:
HP 11592A Service Kit
140/141 Display Section to Spectrum
Analyzer Plug-in Cable Assembly,
Test Extender Assembly (HP 11592-60015)
IF to RF Section Interconnection
Cable Assembly (HP 11592-60016)
Selectro Female to BNC Male Test Cable,
Three each, 36" long (HP 11592-60001)
Selectro Male to Selectro Female Test Cable,
Two each, 8" long (HP 11592-60003)
Selectro Female to Selectro Female Cable,
Two each, 8" long, (HP 11592-60002)
1-8
|
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |