TM 9-4120-411-14
Figure 4-47. Inside Blower Motor.
(1)
Install inside blower motor (14) and orient as illustrated. Secure with four flat washers (13) and screws (12).
(2)
(3)
Remove four screws (1), flat washers (2), and inside blower motor cove r (3).
(4)
Remove locking nut (8). With sealing washer (11) in place, install cable (9) with strain relief fitting (10) into inside
blower motor cover (3) and secure with locking nut. Be sure gasket (15) is in place on cover.
(5)
Connect the ground wire lead at the inside blower motor connections point using flat washer (7), lock washer (6),
and screw (5). Connect the remaining three power leads with three crimp nuts (4) per paragraph 4.16 using tags
and wiring diagram figure 4-14. Remove tags. Connect the two remaining thermal overload leads together with
(6)
Install inside blower motor cover (3) then align mounting holes and secure with four flat washers (2), and screws
(1).
(7)
(8)
Connect FDECU main power cable to power source and operate per paragraph 2.4.