TM 9-4120-404-14
This Task Covers:
a. Removal
b. Installation
Initial Setup:
Tools Required
Tool Kit, Service, Refrigeration, Unit (Item 1, Appendix B)
Material/Parts Required
None
Equipment Condition
Air conditioner shut down and cool.
(1) Remove four screws (1), four lock washers (2), and angle (3).
(2) Remove eight screws (4), four screws (5), four lock washers (6), motor mounting plate ( ), and motor
7
mounting plate (8).
(3) Remove four screws (9), four flat washers (10), and two condenser motor braces (11).
(4) Remove two nuts (12), two lock washers (13), and actuator cylinder (14) from angle (3).
WARNING
Do not allow the unit to swing while suspended from a lifting device. Failure to
observe this warning may result in injury to personnel and damage to the
equipment.
CAUTION
Use care in handling to avoid damage to the air conditioner. If an overhead lifting
device must be used, use an appropriate sling so that the weight of the unit is
supported by the base of the shipping container.
4-34