TM 9-4120-404-14
3-42. EMI FILTER (FL1). - Continued
(2) Remove four nuts (2), four lock washers (3), and four flat washers (4), and remove EMI filter (1) from unit.
b. Test.
(1) Perform continuity check by testing continuity between terminals A, B, C, D, and E of J15 with terminals A,
B, C, D, and E of J16 respectively.
(2) If any test shows an infinite reading, filter must be replaced.
(3) Perform continuity check between E of each plug J15 and J16 and the case. Reading should be zero.
(4) Perform continuity check between E of each plug J15 and J16 and all other terminals. Reading should be
infinity.
c. Installation.
(1) Install EMI filter (1), four flat washers (4), four lock washers (3), and four nuts (2).
(2) Attach P15 to J15 of EMI filter (1).
(3) Attach P16 to J16 of EMI filter (1).
Figure 3-31. EMI Filter.
3-118