TM 9-2330-384-14&P
Table 2-1. Operator Preventive Maintenance Checks and Services (PMCS) (Con't).
M-Monthly
A-After
W-Weekly
D-During
B-Before
ITEM TO BE INSPECTED
INTERVAL
EQUIPMENT IS
NOT READY/
ITEM
PROCEDURE: Check for and have Repaired, Filled, or
NO.
AVAILABLE IF:
B
D
A
W
M Adjusted as required.
TOP OF SEMITRAILER (Con't)
6
WARNING
DO NOT open vent cap. With vent cap
open, vapors inside tank could ignite
if a spark is produced. The resulting
fire and explosion will result in serious
injury or death to personnel.
c. Check for fuel leaks at rear vent cap (41). ANY FUEL LEAKS.
Check that vent cap is not loose. If fuel is leaking
from vent cap, or vent cap is loose, notify unit
maintenance IMMEDIATELY.
Manhole fill cover will
d. Check that manhole fill cover (42) is
not close.
e. Check emergency valve remote trip-release Emergency valve re-
note trip-release is
(3) for looseness or damage.
damaged or missing
Any damage is found
f. Check grounding stud (4) on roadside and
will
prevent
that
curbside overturn rails for looseness or damage,
proper grounding of
Clean any paint, grease, or dirt on grounding
semitrailer.
contact surface. If loose or damaged, notify unit
maintenance.
2-19