4-113. APU JUMP START SYSTEM (CONT)
4.
Remove bolt (7) and tag and remove cable (8) from streetside of APU hydraulic pump. Reinstall and tighten bolt
(7).
5.
If semitrailer is needed for a mission, connect negative (-) cable (1) to negative (-) pole on battery (2). If not
needed for a mission, proceed to step 6.
6.
Remove two locknuts (9) and four cable clamps (10) from cables (5 and 8). Discard locknuts.
7.
Remove four locknuts (11) and bolts (12) and remove electrical box (13) from gooseneck. Discard locknuts.
8.
Using two people, remove bag (14) from crossbar (15) with jump start cables still coiled in bag, for ease of
transport.
9.
Remove cover (16) from electrical box (17).
4-522