5-11. OUTRIGGER ACTUATOR ASSEMBLY REPAIR (Con't).
18.
Press new seal into external threaded ring
(34), with seal identification numbers up, using
seal adapter. Ensure that seal bottoms out.
CAUTION
When Installing external threaded ring over extension cover, DO NOT damage seal.
19.
Apply light film of grease over entire length of
extension cover (31) and install external
threaded ring (34) onto extension cover.
20.
to threads of external threaded ring (34) and
tighten securely with spanner wrench.
21.
to threads of brass tip setscrew (32) and install
brass tip setscrew.
22.
Fill cavity above brass tip setscrew (32) with
5-41