TM 55-1925-282-14&P
0019 00
8. Remove four bolts (figure 2, item 4), eight flat washers (figure 2, item 5), four nylock nuts (figure 2, item 6),
and four rubber grommets (figure 2, item 7) that secure the pump (figure 2, item 8) to the foundation (figure
2, item 9). Discard the nyloc nuts.
9. Remove the fresh water flush pump (figure 2, item 8).
10. Remove the outlet fitting (figure 3, item 2) from the fresh water flush pump (figure 3, item 3).
11. Remove the inlet strainer (figure 2, item 10) from the fresh water flush pump (figure 2, item 8)
3
2
1
Figure 3. Fresh Water Flush Pump (Outlet Side)
INSTALLATION
1. Perform the Service Fresh Water Flush Pump Inlet Strainer procedure (WP 0014 00).
2. Install the inlet strainer (figure 2, item 10) on the fresh water flush pump (figure 2, item 8).
3. Install the outlet fitting (figure 3, item 2) in the fresh water flush pump (figure 3, item 3).
4. Place the fresh water flush pump (figure 2, item 8) on the foundation (figure 2, item 9), and secure it in place
with four bolts (figure 2, item 4), eight flat washers (figure 2, item 5), 4 rubber grommets (figure 2, item 7) and
four new nylock nuts (figure 2, item 6).
5. Install the inlet hose (figure 2, item 2), and secure it with the hose clamps (figure 2 item 1).
0019 00-3