ABSORPTION POWER METERS
Up
Neets Module 21-Test Methods and Practices
Next
Bolometer

3-17 Figure 3-14.—Vhf-uhf wattmeter. In-Line Wattmeters The AN/URM-120 in-line wattmeter, shown in figure 3-15, measures power applied to a 50-ohm impedance load and the power reflected from that load. The internal directional coupler is oriented such that it responds only to a wave traveling in one direction on the transmission line. The coupler can be rotated to accommodate either incidental or reflected power. The rf is then rectified, filtered, and applied to the meter, which is scaled in watts. The rf power of 50 to 1,000 watts can be measured between the frequencies of 2 MHz to 30 MHz; and 10 to 500 watts, between the frequencies of 30 MHz to 1,000 MHz. Figure 3-15.—Typical in-line wattmeter.