14190_22

1-9 Figure 1-6.—Duty cycle. Since the duty cycle of a radar is usually known, the most common formula for average power is expressed as: Transposing the above formula gives us a common formula for peak power: Peak power must be calculated more often than average power. This is because, as previously mentioned, most measurement instruments measure average power directly. An example is shown below: Where: Before figuring Pp, you must figure duty cycle as follows: Now that you have duty cycle, Pp may be calculated as follows: