![]() ![]() TM 11-6130-385-34
Power
switch.
Section
IX.
RECOVERY
DRIVE
AND
POWER
TRANSFORMERS
C617, C618, and C619 are selected tuning com-
ponents and are not used unless required. Capacitors
C601 through C610 act as a storage cell for the dc
The recovery drive transformers are located on
input to the unit and provide an additional source of
Module A9. Input from the recovery drive circuit on
c u r r e n t to supply the circuits when instantaneous
the oscillator board (A1) is applied and transferred
d e m a n d s exceed the 28-vdc source.
as 2V signals to the recovery drive circuit on module
A7 chassis.
3-40. Output Filter
3-39. Power Transformer Circuit
The output filter is an encapsulated unit and is
i l l u s t r a t e d for circuit continuity purposes only. Do
T h e power transformer (T1) and capacitors (C611
n o t make any repairs to this unit.
through C619) provide a step-up of 30 vac to 115 vac
at 400 Hz, 3 phase, to the output filter. Capacitors
|
|