TM 1-1730-231-13&P 3-30.  RESERVOIR TANK 3-30 This task covers: A.  INSPECTION B.  REPAIR (AVIM) C.  REMOVAL D.  INSTALLATION INITIAL SETUP Tools Tool Kit, Hydraulic, NSN 5180-00-323-4891 Shop Set, AVIM, Hydraulic, NSN 4920-00-165-1454 Parts Required Gasket, P/N 20079-03 Personnel Required MOS 67 General Safety Instructions WARNING Be sure that all electrical power is removed from the    unit    before    beginning    any    maintenance operation. To  avoid  personnel  injury,  the  pump  must  be shut  down  before  beginning  any  maintenance operation. NOTE Tag all disconnected tubing to ease reinstallation. A. INSPECTION 1. Check fluid level to make sure it is to the center of the OPNL LEVEL sight glass (1). 2. Check all tubing and line connections for leaks. 3. Check reservoir tank (2) for physical damage. GO TO NEXT PAGE 3-42