Figure  1-8.   Typical  Metal  Sorting  Display
Up
TM-1-1520-265-23 H-60 Helicopter Series Manual
Next
Acceptance/Rejection Criteria

TM 1-1520-265-23 WARNING Electrical equipment shall not be operated in areas where combustible gases or vapors may be present, unless the equipment is explosion-proof. a. If instrument is operated using AC power, use a grounded power cord. b. Turn power OFF before connecting or disconnecting transducer cable or power cable. 1.4.12.2 Ultrasonic Instrument Standardization.   The ultrasonic instrument used in ultrasonic inspection procedures described  throughout  this  manual  is  listed  in  Table  1-7.    Reference  blocks,  instrument  settings,  and  standardization instructions  for  the  ultrasonic  instrument  are  included  in  the  individual  ultrasonic  inspection  procedures.    Because  of varied  circumstances  under  which  the  inspections  may  be  performed,  instrument  settings,  as  they  are  given  in  this manual, should be considered typical.  Slight adjustment to the settings may be necessary to achieve the desired CRT presentation.      Illustrations   representing   typical   CRT   presentation   will,   in   most   cases,   include   reference   signals representing  initial  pulse,  transducer,  and/or  wedge  echoes  that  have  been  moved  off  the  scope  to  make  room  for relevant indications.  An effective ultrasonic inspection will depend largely upon the proper handling of the transducer; therefore, the following steps are recommended: a. Clean  ultrasonic  transducer  with  a  low-lint  cloth,  MIL-C-85043  or  equivalent.    Clean  all  contact  surfaces  when using a wedge or delay block.  Apply couplant to these contact surfaces and carefully tighten the assembly prior to test. NOTE Scratches  or  similar  surface  blemishes  remaining  on  the  transducer  or  wedge  may  give  false indications. b. Use prescribed or equivalent couplant and in sufficient quantity to achieve proper coupling.  The use of lubricants containing graphite, silicones, and glycerines is prohibited. c. Apply adequate pressure to keep transducer in contact with part. d. Use moderate speed for transducer search pattern.  If transducer movement is too fast, a flaw could be passed over without a proper indication. 1-36

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing