Figure 1-6.  Portable Magnetic Particle Inspection Equipment
Up
TM-1-1520-265-23 H-60 Helicopter Series Manual
Next
Radiation Hazard

TM 1-1520-265-23 1-30    Change 2 CAUTION Do not operate magnetic particle equipment within 36 inches of aircraft instruments. 1.4.9 Demagnetization of Inspection Parts.  Following magnetic particle inspection of a part, the residual magnetic field in the part shall be reduced to the lowest possible level. This must be done prior to returning the part to service or rejecting it as a defective part. Unless this is done properly, the residual magnetism may cause adverse influence on instruments, unnecessary wear on parts, or attract ferrous metal chips and dust into bearing surfaces. After demagnetization, a magnetic field strength meter shall be used to measure residual fields. Readings in excess of three units are not acceptable. 1.4.9.1 Demagnetization Using AC.   If AC demagnetization is selected, hold the part about 12 inches in front of the coil. Move it slowly and steadily through the coil to at least 36 inches beyond the end of the coil while current is still flowing. Repeat process as necessary. Rotate and tumble parts of complex configuration while passing through the coil field. All parts can be demagnetized using a contour probe in the AC mode. Place the probe against the magnetized part with the switch in AC position. Turn probe on and withdraw it from the part, or the part from the probe/yoke, about 24 inches before turning the probe off. 1.4.9.2 Demagnetization Using DC.  If DC demagnetization is selected, the initial demagnetizing field shall be higher than, and in nearly the same direction as, the field reached during inspection. The field shall then be reversed and decreased in magnitude, and the process repeated (cycled) until an acceptable low value of residual field is reached. Whenever possible, parts that have been circularly magnetized shall be magnetized in the longitudinal direction before being demagnetized. This procedure is limited to stationary equipment. 1.4.10   Radiographic (RT) Method. NOTE Radiographic  inspection  shall  be  performed  in  accordance  with  the  general application and techniques in TM 1-1500-335-23 (Nondestructive Inspection Methods manual) and the specific requirements of this technical manual. Radiographic inspection is used to detect internal and external structural details of all types of parts and materials. This method is used for the inspection of airframe structure for damage, detection of moisture entrapment, structure alignment, and foreign object intrusion. It can sometimes be used in areas otherwise inaccessible to other nondestructive inspections and to verify indications observed by other methods. Radiographic inspections are accomplished by passing the X-ray beam through the part or assembly to expose a radiographic film emulsion or other sensitized medium. The processed film shows the structural details of the part by variations in film density. Requirements for film density, image quality indicator, identification, and other factors are specified in MIL-STD-453.

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing