PACKAGE FUEL CONTROL (Continued)
Up
TM-55-2840-254-23-4 Engine Gas Turbine Model T55-L-712 Manual
Next
REMOVE FUEL BOOST PUMP ASSEMBLY (Continued)

TM 55-2840-254-23
Section Ill. FUEL BOOST PUMP ASSEMBLY ­ MAINTENANCE PROCEDURES
6-9
6-9 REMOVE FUEL BOOST PUMP ASSEMBLY
General Safety Instructions:
INITIAL SETUP
Applicable Configurations:
All
Tools:
Powerplant Mechanic's Tool Kit,
Turbine fuels are very flammable. They
NSN 5180-00-323-4944
may cause drying and irritation of skin
Container, 1 Quart
or eyes. Handle only in well-ventilated
areas away from heat and open flame.
Drain and store in approved metal
Materials:
Wiping Rag(E58)
safety containers. Avoid prolonged or
repeated contact with skin and do not
take internally. Wash contacted area
Personal Required:
68B10 Aircraft Powerplant Repairer
of skin thoroughly after handling. If
irritation of skin results, get medical
attention. Get medical attention for
eyes.
GO TO NEXT PAGE