![]() ![]() TM 55-2840-254-23
Section II FUEL CONTROL - PREPARATION FOR STORAGE OR SHIPMENT
6-7
General Safety Instructions:
All
Lubricating oil (E31) can cause paralysis
Tools:
Powerplant Mechanic's Tool Kit,
if swallowed. Prolonged contact with it
NSN 5180-00-323-4944
may irritate the skin. Handle only in
Hose Assembly (Appendix E) (2)
well-ventilated areas away from heat and
Socket Wrench Handle
flame. Drain and store in approved metal
Container, 2 Gallon (2)
safety containers. Avoid prolonged or
repeated contact with skin and do not
take internally. Wash contacted areas of
Materials:
High Pressure Caps
skin thoroughly after handling. If irrita-
Lubricating Oil (E31)
tion of skin results, get medical attention.
Get medical attention for eyes.
Personal Required:
681310 Aircraft Powerplant Repairer (2)
Equipment Condition:
Off Engine Task
Fuel Control Removal (Task 6-1)
NOTE
If fuel control is removed from engine
and is not to be reinstalled for a period
longer than 46 hours, it must be pre-
Served.
1. Place fuel control (1) in horizontal position.
2. Install three high pressure caps (2) on three
fittings (3).
GO TO NEXT PAGE
|
|