DISASSEMBLE FUEL CONTROL (Continued)
Up
TM-55-2840-254-23-4 Engine Gas Turbine Model T55-L-712 Manual
Next
CLEAN FUEL CONTROL (Continued)

TM 55-2840-254-23
6-3
6-3 CLEAN FUEL CONTROL
INITIAL SETUP
Equipment Condition:
Off Engine Task
Fuel Control Removed (Task 6-1)
Applicable Configurations:
Fuel Control Disassembled (Task 6-2)
All
Tools:
General Safety Instructions:
Goggles
Compressed Air Source
Materials:
Dry Cleaning Solvent (E17)
Dry cleaning solvent (E17) is flammable
Gloves (E20)
and toxic. It can irritate skin and cause
Wiping Rag (E58)
burns. Use only in well-ventilated area,
away from heat and open flame. In case
Personnel Required:
of contact, immediately flush skin or
68B10 Aircraft Powerplant Repairer
eyes with water for at least 15 minutes.
Get medical attention for eyes.
1. Wear gloves (E20). Clean fuel control (1) with
wiping rag (E58) dampened in dry cleaning
solvent (E17).
GO TO NEXT PAGE