TM  55-2835-209-23 1-22 VISUAL INSPECTION OF APU (CONT) 12. Inspect aft engine mounts (8) for cracks. No cracks allowed. 13. Inspect  inside  turbine  combustor case (9) for oil leakage. No oil leakage allowed. 14. Inspect  turbine  housing  (10)  for cracks. No cracks allowed. 15. Inspect  compressor  inlet  and  cylin- der (11) for security or puncture holes. No puncture holes allowed. 16. Inspect  compressor  housing  (12)  for cracks. No cracks allowed. 17. 18. 19. 20. 21. Inspect  hourmeter  assembly  (13)  for cracked  glass. No cracks allowed. Inspect  igniter  plug  lead  (14)  for frayed cover or pinched areas. No frayed cover or pinched areas al- lowed. Inspect Ignition unit (15) for se- curity,  cracks,   discoloration  or bulging. No  cracks,  discoloration or bulging allowed. Inspect  fuel  manifold  assembly  (16) for chaffing or evidence of leaks. No chaffing or leaks allowed. Inspect  immersion  thermocouple  (17) and wiring for security and damage. No damage allowed. 1-18 Change 1

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing