TM  55-2835-208-23 2-5 INSPECT COMPRESSOR ROTOR (Continued) 2-5 4. Using a machinists scale and a small mirror, measure the depth of any   eroded areas near the root  of the compressor blade (1) Measure short blades  (2)  as well as long blades  (3). Erosion up to 0.060 inch depth  permits  continued APU  operation  but  requires a 10 hour APU operation inspection cycle. Maximum use is 50 hours or until the availability of a replacement APU. 5. Erosion at blade roots shall not exceed 0.125 inch depth, measured axially from blade leading edge (4). Replace APU assembly if erosion exceeds 0.125  inch. GO TO NEXT PAGE 2-11