Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Table 2-4. Troub leshooting - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Table 2-4. Troub leshooting - continued
Up
TM-5-6115-612-34 Gas Turbine Engine Driven Aviation Generator Set Manual
Next
Table 2-4. Troub leshooting - continued

ARMY TM  5-6115-612-34 MARINE CORPS TM 6115-34/8 AIR  FORCE TO  35C2-3-471-2 NAVY AG-320BO-MME-OOO 2-3. GENERAL. (cont) Table 2-4. Troub leshooting - continued MALFUNCTION TEST  OR  INSPECTION CORRECTIVE  ACTION 9. CONTACTOR CLOSED INDICATOR LIGHT WILL NOT COME ON - PROBLEM ISOLATED TO EECM. Step  1. Check wires from J6-T to switch circuit card P2-21 and from J6-S to switch board P2-19. Repair  or  replace  as  necessary. Step 2. Connect EECM under test to EECM tester. Place MASTER SWITCH in START position and release to RUN position. Inject a signal into  SPEED  input. Increase frequency to 3352 Hz ± 67 Hz. Connect voltmeter to P1-1(+) and to E1(-) ground terminal. Read voltage. If voltage is less than 1.5 Vdc, replace switch circuit card  (paragraph  10-2b). If voltage is more than 1.5 Vdc, replace microprocessor circuit  card  (paragraph  10-2b). 10. NO OUTPUT VOLTAGE - PROBLEM ISOLATED TO EECM. Step  1. Perform  steps  under  Malfunction  6. 11. UNDERVOLTAGE MALFUNCTION LIGHT COME ON - OUTPUT VOLTAGE NORMAL. Step  1. Connect GECM to test fixture in accordance with paragraph 4-2a. If UNDER VOLTS light comes on, go to Step 2. If UNDER VOLTS light off, go to Step 5. Step 2. Increase power supply 2 output voltage to 20 (± 1) Vdc. If UNDER VOLTS light goes off, go to Malfunction 17. If UNDER VOLTS light stays on, go to Step 3. Step  3. Use voltmeter to check voltage at circuit card connector P1-39 (+) and P1-38(-). If voltage reads same as power supply 2 output voltage, go to Step 4. 2-47

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing