Back
Figure 3-10. Inspection  of  Running  Gear
Up
TM-5-6115-612-12 Generator Set Diesel Engine Driven Tactical Skid Mtd. 600 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
INSPECTING   AND   SERVICING THE EQUIPMENT

ARMY TM  5-6115-612-12 MARINE  CORPS  TM  6115-12/7 AIR  FORCE T0 35C2-3-471-1 NAVY AG-320B0-0MM-000 CHAPTER  4 ORGANIZATIONAL MAINTENANCE Section I. SERVICE UPON RECEIPT OF EQUIPMENT 4-1. INSPECTING   AND SERVICING   THE EQUIPMENT. a. General. The generator set shall be uncrated, inspected,  and  ser- viced in accordance with the following procedures. b. Remove Generator Set from Packing Crate. (1)  Cut  and  remove  steel  band- ing. Carefully disassemble or lift top portion  of  crate  from  generator  set. (2)  Remove  all dunnage, cush- ioning, blocking, and bracing material away from generator set. (3) Remove blocking and attaching hardware  anchoring  generator  set  to skid. (4) Remove all sealing tape. Open all access doors and covers. Remove all desiccants,  packings,  and  barriers  from inside  all  compartments. c. Inspect Generator Set for Damage. The  generator  set  shall  be inspected  for  damage,  disconnections, and missing parts. See figures 1-1 and 1-2 for locations. (1) Raise control panel access door. Inspect  control  panel  for  evi- dence of cracked and broken instruments and controls. All gage readings except hourmeter should be at zero. Hourmeter will show   number   of   test   hours   on generator  set. (2) Loosen turnlock fasteners and open  control  panel. Ensure that all wiring  is in  place with  connectors tight    at terminals    of controls, indicators, and terminal strip. Remove and discard all desiccant, packing, and barriers. Close  and  secure  control panel  . (3) Remove power cable from cable support assembly and inspect cable for cracks, abrasions, and cuts. Check output  connector  for  damage. (4) Unlatch and open fuel housing access  door. Secure door in open posi- tion. Inspect fuel system lines and components for damage. Ensure that fuel lines are tight. Close and se- curely  latch  fuel  housing  access  door. (5) Inspect battery for damage. (6)  Unlatch  and  open  inlet  air housing access door. Secure door in open  position. (7) Check air baffle, air filter and air inlet louvers for damage and foreign material. Ensure that  all lines, fittings, wiring, and connectors are secure. Close and securely latch inlet air housing access door. (8)   Stow   power   cable   on   cable support  assembly. (9) Ensure that exhaust door is free of obstruction. (10)  Loosen turnlock fasteners and  remove  engine  housing  access  cover. 4-1