Table 3-2. Preventive Maintenance Checks and Services (PMCS) - Continued
Up
TM-5-6115-612-12 Generator Set Diesel Engine Driven Tactical Skid Mtd. 600 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Section V. OPERATOR/CREW MAINTENANCE INSTRUCTIONS

A R MY TM  5-6115-612-12 MARINE CORPS TM 6115-12/7 AIR  FORCE TO 35C2-3-471-1 NAVY AG-320B0-0MM-000 Section  IV.  TROUBLESHOOTING 3-5. GENERAL. a. Table 3-3   provides trouble- shooting  information  for  locating  and correcting problems that may develop in the generator set. Each malfunction for  an  individual  component,  unit,  or system is followed by a list of tests or Inspections that will help determine probable causes and corrective actions to take. Perform the tests/inspections and  corrective  actions  in  the  order listed. b.  This  manual cannot   list   all malfunctions  that  may  occur. If  a malfunction is not listed or cannot be corrected by listed corrective actions, notify  supervisor. NOTE Before using this table, ensure that   all   applicable   operating checks have been performed. Table  3-3.  Troubleshooting MALFUNCTION TEST  OR  INSPECTION CORRECTIVE  ACTION 1. STARTER ROTATES ENGINE, BUT COMBUSTION DOES NOT OCCUR. Step 1. Check to ensure adequate fuel supply. Fill fuel tank. Step 2. Unit still fails to operate. Refer to next higher level of maintenance. 2. MASTER SWITCH IS PLACED IN THE START POSITION, BUT ENGINE DOES NOT ROTATE. Step 1. Check  that Refer to Step 2. Check  that Press DC no malfunction indicator light is on. higher level of maintenance if malfunction light is on. DC CIRCUIT BREAKER reset button is pressed in. CIRCUIT BREAKER reset button to reset. Step  3. Check  battery  cable  plug  connector. Tighten  battery  connector. Step 4. Unit still fails to operate. Refer to next higher level of maintenance. 3-8 PIN: 060184-004