Figure  1-4. Lubrication  System  Simplified  Block  Diagram
Up
TM-5-6115-612-12 Generator Set Diesel Engine Driven Tactical Skid Mtd. 600 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Table  2-1.  Controls  and  Indicators  -  Continued

FAARMY TM  5-6115-612-12 MARINE  CORPS  TM  6115-12/7 AIR  FORCE TO 35C2-3-471-1 NAVY AG-320B0-0MM-000 CHAPTER  2 OPERATING   INSTRUCTIONS Section I. OPERATING   PROCEDURES 2-1. GENERAL. This   section   contains   2-2.   CONTROLS   AND   INDICATORS.    In- procedures for operating the generator formation on description, function, and set  under  normal conditions. These normal operating positions of controls procedures are intended to familiarize and indicators is listed in table 2-1. the operator with control and operation Control  panel  controls  and  indicators of the generator set. are shown in figure 2-1. Table  2-1.  Controls  and  Indicators Control  or Function Normal  operating indicator position MASTER  SWITCH Toggle  switch CONTACTOR Toggle  switch READY  TO  LOAD Light  indicator CLOSED Light  indicator VOLTAGE DC  voltmeter VOLTAGE  ADJUST Potentiometer OUTPUT CURRENT Output ammeter BATTERY  CHARGING Battery  charg- ing  ammeter DC  CIRCUIT  BREAKER (Pushbutton  - press-to-reset) Three-position  toggle  switch. RUN RUN  activates  electrical and fuel systems. START position  starts  engine.  OFF position  shuts  generator  set  OFF. Opens  and  closes  contactor. Illuminates  when  set  is  run- ning at 100% rpm (green). Illuminates  when  contactor is closed (yellow). Provides indication of dc volts. Adjusted  to  maintain output  voltage. Provides  indication  of  output amperage. Provides  indication  of  battery charging rate. Provides  protection  for  dc electrical  system. CLOSED off On 28 Vdc Midrange Variable To right of zero Reset  button pushed in 2-1