Figure 2-7.  Instrument Panel (60 Hz Electrical).  (TS 6115-590-12/2-7)
Up
TM-5-6115-590-12 Generator Set Engine Driven Tactical Skid Mtd 10 Kw 1 Phase - 2 Wire 1 Phase - 3 Wire 3 Phase - 4 Wire Manual
Next
Figure 2-9.  Receptacle and Remote Power Panels (TS 6115-990-12/2-9)

TM 5-6115-590-12 Figure 2-8.  Instrument Panel (400 Hz Electrical).  (TS 6115-590-12/2-8). a.  Frequency Meter. (1)    Description.        Dial    pointer    gauge,    calibrated    to indicate  388  to  412  hertz  per  second  in  1/2  hertz  per second increments.  The dial scale has a red index mark at 400 hertz per second. (2)  Purpose.    To  indicate  the  output  frequency  of  the 400 Hz electrical system. (3) Indication.  Normal indication is 400 Hz per second. b.  AC Ammeter (1)    Description.        Dial    pointer    gauge,    calibrated    to indicate percent of rated current.  The dial is calibrated from 0 to 125 percent in 5 percent increments. (2)  Purpose.   To  indicate  the  line-to-neutral  current  as selected    through    the    volt-amp    select    switch    during operation of the power unit (3)   Indication.      Normal   operating   range   Is   0   to   100 percent.    Ammeter  readings  over  100  percent  indicate an overload condition. c.  AC Voltmeter (1)    Description.        Dial    pointer    gauge,    calibrated    to indicate 0 to 150 V AC m 5 volt increments. (2)    Purpose.       Indicates    line-to-neutral    voltages,    as selected    through    the    volt-amp    select    switch    during operation of the power unit. (3) Indication.  Normal operating indication Ls 120V AC, as  determined  by  the  position  of  the  volt-amp  select switch. d.  Volt-Amp Select Switch. (1) Description.  A four position rotary stitch. (2)   Purpose.       Connects   the   AC   ammeter   and   AC voltmeter  for  selective  monitoring  of  the  line-to-neutral voltages and currents An OFF position is also provided to disconnect the ammeter and voltmeter. e.  Output Contactor Switch. (1) Description.  A three position toggle switch. (2)  Purpose.     In  the  momentary  RESET  position  the switch actuates the 400 Hz output contactor to reset and close    the    output    contacts    connecting    the    400    Hz electrical  system  to  the  external  load.    When  released, the switch returns to the CLOSE position.  In the OPEN position  the  switch  actuates  the  contactor  to  open  the output contacts and disconnect 2-10 Change 9