Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Figure 2-7. Instrument Panel (60 Hz Electrical). (TS 6115-590-12/2-7)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Figure 2-6.  Conditioned Air Temperature Control Panel (TS 6115-590-12/2-6)
Up
TM-5-6115-590-12 Generator Set Engine Driven Tactical Skid Mtd 10 Kw 1 Phase - 2 Wire 1 Phase - 3 Wire 3 Phase - 4 Wire Manual
Next
Figure 2-8.  Instrument Panel (400 Hz Electrical).  (TS 6115-590-12/2-8)

TM 5-6115-590-12 Figure 2-7.  Instrument Panel (60 Hz Electrical).  (TS 6115-590-12/2-7) calibrated     from     0     to     125     percent     in     5     percent increments.    The  dial  range  is  colored  red  from  100  to 125 percent. (2)  Purpose.     To  indicate  the  line-to-line  and  line-to- neutral  current  as  selected  through  the  volt-amp  select switch during operation of the power unit. (3)   Indication.      Normal   operating   range   is   0   to   100 percent.    Ammeter  readings  over  100  percent  indicate an overload condition. c.  AC Voltmeter. (1)    Description.        Dial    pointer    gauge,    calibrated    to indicate 0 to 300V AC in 10 volt increments. (2)   Purpose.     Indicates   line-to-line   and   line-to-neutral voltages, as selected through the volt-amp select switch during operation of the power unit. (3)  Indication.    Normal  operating  indication  is  120  or 240V AC as determined by the position of the volt-amp select switch. d.  Volt-Amp Select Switch. (1) Description.  A four position rotary switch. (2)   Purpose.       Connects   the   AC   ammeter   and   AC voltmeter for selective monitoring of the line-to- line and two-line-to-neutral    voltages    and    currents.        An    OFF position is also provided to disconnect the ammeter and voltmeter. e.  Load Contactor Switch. (1) Description.  A three position toggle switch. (2) Purpose.  In the CLOSE position the switch actuates the    60    Hz    power    output    contactor    to    close,    thus connecting  the  60  Hz  electrical  system  to  the  external load.      In   the   OPEN   position   the   switch   actuates   the contactor   to   open   and   disconnect   the   load.      In   the RESET position the switch resets the protective circuits in  the  generator  control  panel  if  the  load  contactor  trip light is on. f.  Load Contactor Trip Indicator Lamp. (1) Description.  A filament type press-to-test lamp with a red lens. (2)   Purpose.         Illuminates   to   indicate   that   the   load contactor has tripped to disconnect the load from the 60 Hz electrical system. 2-7.        400    Hz    Electrical    System    Controls    and Instruments (fig.  2-8) The  400  Hz  electrical  system  controls  and  instruments are  located  on  the  instrument  panel.    The  description, purpose,  and  function  of  the  400  Hz  electrical  system controls   and   instruments   for   the   power   unit   400   Hz electrical system are described as follows: 2-9

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing