Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Figure 2-5. Conditioned Air Circuit Breaker Panel. (TS 6115-59012/2-5)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Figure 2-4.  Instrument Panel (Conditioned Air System Controls).  (TS 6115-590-12/2-4)
Up
TM-5-6115-590-12 Generator Set Engine Driven Tactical Skid Mtd 10 Kw 1 Phase - 2 Wire 1 Phase - 3 Wire 3 Phase - 4 Wire Manual
Next
Figure 2-6.  Conditioned Air Temperature Control Panel (TS 6115-590-12/2-6)

TM 5-6115-590-12 Figure 2-5.  Conditioned Air Circuit Breaker Panel.  (TS 6115-59012/2-5) s.    Cooled  Air  System  Indicating  Lamp  (No.  2  system) (fig.  2-6). (1) Description.   A filament type press-to-test lamp with a green lens. (2)   Purpose.      Illuminates   to   indicate   that   the   No.   1 cooled air temperature control is calling for cooling. t.  Cooled Air System Indicating Lamp (No. 2 system). (1) Description.   A filament type press-to-test lamp with a green lens. (2)   Purpose.      Illuminates   to   indicate   that   the   No.   2 cooled air temperature control is calling for cooling. u.        Cooled    Air    System    Temperature    (Thermostat) Control (No. 1 system). (1)    Description.        An    electronic    thermostat    control, connected to the thermister-temperature-sensitive elements in the return air ducts. (2)  Purpose.    Provides  progressive  adjustment  of  the cooled air output temperature from the No. 1 cooled air system.    Lowers  the  output  temperature  when  rotated counterclockwise   and   raises   the   output   temperature when rotated clockwise. v.        Cooled    Air    System    Temperature    (Thermostat) Control (No. 2 system). (1)    Description.        An    electronic    thermostat    control, connected to the thermister-temperature-sensitive elements in the return air ducts. (2)  Purpose.    Provides  progressive  adjustment  of  the cooled air output temperature from the No. 2 cooled air system.    Lowers  the  output  temperature  when  rotated counterclockwise   and   raises   the   output   temperature when rotated clockwise. w.  Heat Range Select Switch (No. 1 system). (1) Description.  A four position rotary switch. (2)  Purpose.   Selects  one  of  the  three  heating  ranges (LOW, MED, HIGH) as desired for the No. 1 heated air system.  Limits the travel of the heat control valve in the opening direction (26 percent, 50 percent and full open). Provides an OFF position for shutdown of the heated air system. x.  Heat Range Select Switch (No. 2 system). (1) Description.  A four position rotary switch. (2)  Purpose.   Selects  one  of  the  three  heating  ranges (LOW, MED, HIGH) as desired for the No. 2 heated air system.  Limits the travel of the heat control valve in the opening direction (25 percent, 50 percent and full open). Provides an OFF position for shutdown of the heated air system. y.      Heated   Air   System   Temperature   Control   (No.   1 system). (1)    Description.        An    electronic    thermostat    control, connected to thermistor-temperature-sensitive elements in the return air ducts. (2)  Purpose.    Provides  progressive  adjustment  of  the heated  air  output  temperature  within  the  heating  range selected by the heat range select switch, from the No. 1 heated air system.  Lowers the output temperature when rotated counterclockwise and raises the output temperature when rotated clockwise. Change 6 2-7

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing