Back
Figure 2-3.  Instrument Panel (Auxiliary Power Outputs Controls) (TS 6115-590-12/2-3)
Up
TM-5-6115-590-12 Generator Set Engine Driven Tactical Skid Mtd 10 Kw 1 Phase - 2 Wire 1 Phase - 3 Wire 3 Phase - 4 Wire Manual
Next
Figure 2-5.  Conditioned Air Circuit Breaker Panel.  (TS 6115-59012/2-5)

TM 5-6115-590-12 Figure 2-4.  Instrument Panel (Conditioned Air System Controls).  (TS 6115-590-12/2-4). (2)   Purpose.      Illuminates   to   indicate   that   the   power contactor to the No. 2 system compressor has tripped to open the power circuit to the compressor motor. NOTE The     press-to-test     feature     of     the     air     conditioning compressor    trip    indicators    (system    1    and    2)    allow operator to check circuit (Bulb).  They are to be checked only with the unit in operation and main 400HZ contactor closed. l.  Recirculating Fan Circuit Breaker (No. 1 system) (fig. 2-5). (1) Description.  A press-to-reset circuit breaker installed in the No. 1 system recirculating fan power circuit. (2)   Purpose.      Provides   short   circuit   and   over.   load protection  for  the  No.  1  system  recirculating  fan  power circuit.      The   circuit   breaker   opening   amperage   (20 amps) is marked on the reset button. m.  Condenser Fan Circuit Breaker (No. 1 system). (1) Description.  A press-to-reset circuit breaker installed in the No. 1 system condenser fan power circuit. (2)   Purpose.       Provides   short   circuit   and   over   load protection  for  the  No.  1  system  condenser  fan  power circuit.      The   circuit   breaker   opening   amperage   (50 amps) is marked on the reset button. n.  Deleted o.  Recirculating Fan Circuit Breaker (No. 2 system) (fig. 2-5). (1) Description.  A press-to-reset circuit breaker installed in the No. 2 system recirculating fan power circuit. (2)   Purpose.       Provides   short   circuit   and   over   load protection for the No. 2 system recirculating fan 2-6 Change 6