Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Figure 2-1. Instrument Panel (Gas Turbine Engine Controls and Instruments (TS 6115-590-12/2-1)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
CHAPTER 2 OPERATING INSTRUCTIONS
Up
TM-5-6115-590-12 Generator Set Engine Driven Tactical Skid Mtd 10 Kw 1 Phase - 2 Wire 1 Phase - 3 Wire 3 Phase - 4 Wire Manual
Next
Water Systems Controls

TM 5-6115-590-12 Figure 2-1.  Instrument Panel (Gas Turbine Engine Controls and Instruments (TS 6115-590-12/2-1) complete the starting sequence.  The master switch also functions as an engine stop switch by de-energizing the engine   24V   DC   control   circuit   when   placed   in   OFF position. CAUTION Do not hold master switch in start position after engine starts to rotate. k.  Generator Control Circuit Breaker. (1) Description.  A press-to-reset circuit breaker installed in the 60 Hz and 400 Hz generator control circuits. (2)    Purpose.        Provide    short    circuit    and    overload protection  for  the  generator  control  circuits  The  circuit breaker opening amperage (15 amps) is marked on the reset button. I.  Turbine Control Circuit Breaker. (1) Description.  A press-to-reset circuit breaker installed in the engine control circuit. (2)    Purpose.       Provides    short    circuit    and    overload protection   for   the   engine   control   circuit.      The   circuit breaker opening amperage (10 amps) is marked on the reset button. m.  Remote Operation Switch. (1) Description.  A three position toggle switch. (2)  Purpose.    When  placed  in  the  OPERATE  RESET position,   the   switch   completes   a   circuit   to   reset   and close    an    output    contactor    to    deliver    power    to    a nonoperating power plant for operation of the ventilating fans in the nonoperating unit.  The switch returns to the center position when released.  When placed in the OFF position, the switch opens the remote output contactor to stop power output to the nonoperating unit. n.  Remote Operation Trip Indicator Lamp. (1) Description.   A filament type press-to-test lamp with a red lens. (2)  Purpose.     Illuminates   to   indicate   that   the   remote power     output     contact     has     tripped     to     open     and disconnected the remote load. NOTE Press-to-test     feature     only     operates     when     unit     is operating and 400HZ contactor is closed. 2-2 Change 5

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing