Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Overall dimensions and weights (cont)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Overall dimensions and weights (cont)
Up
TM-5-6115-590-12 Generator Set Engine Driven Tactical Skid Mtd 10 Kw 1 Phase - 2 Wire 1 Phase - 3 Wire 3 Phase - 4 Wire Manual
Next
Overall dimensions and weights (cont)

TM 5-6115-590-12 Emergency lighting Refrigeration compressor power requirements ..........................10.0 amps power requirement, each Fuel boost pump (alternate): (2 in system) 19.5 .......................................................... kw Manufacturer ....................................Stanadyne (nominal) Part number  .....................................20633 Condenser cooling fan Discharge pressure ..........................15.0 plig (max) power requirement, each Current requirements........................3.25 amps (4 in system) ............................................ 4.9 kw Volts .................................................24V Recirculating fan power ERDL  ...............................................13217E4034 requirement, each (4) 60 Hz electrical system .....................(4 in system) 1.95 kw Rating ...............................................120/240V AC, 60 Water pump power Hz single phase, requirement, each 3-wire (2 in system) ............................................ 0.23 kw Neutral conductor .............................Ungrounded Generator: Internal 60 Hz power Manufacturer  ........................................... Bendix Corp., requirements ....................................None Red Bank Div. Power available for............................Part number 28B94-15-A external requirements .......................12.5 kva, 10kw at Style ......................................................... A 0.80 pf PMG voltage  ............................................ 29 +1 Generator: Type.......................................................... Three phase, 4 Manufacturer ....................................Bendix Corp., wire Red Bank Div. P/F ........................................................... 0.80 Part number  .....................................5188-3-A KVA .......................................................... 120 PMG (permanent .............................. KW  .......................................................... 96 magnet generator)............................. Frequency ................................................ 400 Hz voltage ..............................................23 ± IV Volts.......................................................... 120/208 Type .................................................Single phase, Amps (100% load) ................................... 333 3 wire Rated rpm ................................................ 6000 P/F (power factor)  ............................0.80 Weight ...................................................... 133 lb. KVA ..................................................12.5 (60.38 Kg) KW ...................................................10.0 Frequency.........................................60 Hz Volts .................................................120/ 240V Voltage regulator: Amps (100% load) ............................53 Manufacturer  ........................................... Bendix Corp., Rated rpm  ........................................3,60Red Bank Div. Weight  .............................................118 lb. Part number ............................................. 20B100-2 (53.37 Kg) Style ......................................................... A Type .................................................Solid State Voltage regulator: Volts ......................................................... 120/208 Manufacturer ....................................Bendix Corp., Frequency................................................. 400 Hz Red Bank Div. Phase  ...................................................... 3 Part number  .....................................20B123-1 Adjustable range ...................................... 115 to 125 volts Style  .................................................B line to neutral Type .................................................Solid State Sensing..................................................... Average 3 phase Volts .................................................120/240 (6) Conditioned air system Frequency ........................................60 Hz Heating capacity (at sea Phase ...............................................1 level and ambient Adjustable range ..............................115 to 125 volts temperature-25-F (-4°C)) ......................... 350,000 btu/hr line to neutral Cooling capacity, each Sensing ............................................Average phase system (two systems used) ..................... 10 tons (approx) with high phase (120,000 btu/hr limiting on with 460 cfm overvoltage. make-up air at Average phase 120°F (49°C)) with low phase Refrigerant specification .......................... R114 (Federal control on Specification undervoltage. BB-F-671) (5) 400 Hz electrical system...................Refrigerant capacity: Rating ...............................................120/208V AC, 400 System No. 1 (lower)  ............................... 39 lb.  (approx) Hz three phase, (17.7 Kg) 4-wire System No. 2 (upper) ............................... 36 lb.  (approx) Neutral conductor .............................Grounded (16.3 Kg) Output: Refrigerant operating Total  .................................................120 kva, 96 kw at pressure.................................................... 70 to 90 psig 0.80 P/F ............................................Refrigerant maximum External with air pressure ................................................... 135 +7 psig conditioning or Refrigeration oil capacity- heating  .............................................30 kw System No. I (lower)  ................................ 590 cc (approx) External with no air (1.24 pt) conditioning or System No. 2 (upper) ............................... 540 cc (approx) heating  .............................................90 kw (1.14 pt) Change 6 1-31

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing