Back
Figure 1-8(2).  Conditioned Air System (Sheet 2 of 2).  (TS 6115-590-12/1-82)
Up
TM-5-6115-590-12 Generator Set Engine Driven Tactical Skid Mtd 10 Kw 1 Phase - 2 Wire 1 Phase - 3 Wire 3 Phase - 4 Wire Manual
Next
Figure 1-10.  Heated Air System Schematic.  (TS 6115-590-12/1-10)

TM 5-6115-590-12 TS 6115-590-12/1-9 Figure 1-9.  Cooled Air System Schematic.  (TS 6115-590-12/1-9). The   accessory   components   consist   of   the   following items. (1)   One external battery DC power cable assembly for connection of external battery from a military vehicle equipped with a 24V DC output receptacle to the power plant for auxiliary starting power. (2)   One  external  DC  electrical  power  input  cable assembly  for  connection  of  an  external  24V  DC  power source. (3)   One  DC  electrical  power  input  cable  assembly for  connecting  the  24V  DC  systems  of  two  power  units together  to  provide  for  standby  operation  of  one  power plant. (4)   One 400 Hz auxiliary power cable assembly for connection  between  power  plants  for  remote  operation of ventilating fans. (5)   One    400    Hz    electrical    power    output    cable assembly   for   connection   of   the   power   plant   400   Hz electrical    system    to    other    elements    of    the    MUST hospital as required. (6)   One    60    Hz    electrical    power    output    cable assembly   for   connection   of   the   power   plant   60   Hz electrical    system    to    other    elements    of    the    MUST hospital as required. (7)   One compressed air hose assembly for connection  of  the  power  plant  compressed  air  outlet  to the  MUST  hospital  inflatable  elements  for  delivery  of inflation air. (8)   One  electrically  heated  water  supply  and  drain water hose assembly for connection of an external water source to the power plant water system. (9)   One electrically heated dual water hose assembly    for    connection    of    the    power    plant    water system to other elements of the MUST hospital. (10) One inflation ejector assembly used to inflate the inflatable elements of the MUST hospital. (11) Eight    conditioned    air    duct    assemblies    for connection of the power plant conditioned air system to other elements of the MUST hospital. 1-17