INSTALL INLET HOUSING COVER ASSEMBLY (AVIM) (Cont)
Up
TM-1-2840-252-23-2 Engine Gas Turbine Model T55-L-714 Manual
Next
INSPECT AIR INLET HOUSING ASSEMBLY

TM 1-2840-252-23-2
SECTION X
AIR INLET HOUSING ASSEMBLY
2-49 CLEAN AIR INLET HOUSING ASSEMBLY
2-49
INITIAL SETUP
General Safety Instructions
:
WARNING
Applicable Configurations:
All
Dry cleaning solvent (E19) is flammable
Tools:
and toxic. It can Irritate skin and cause
None
burns. Use only in well-ventilated area,
Materials:
away from heat and open flame. In case
Dry Cleaning Solvent (E19)
of contact, Immediately flush skin or
Gloves (E24)
eyes with water for at least 5 minutes
1
Wiping Rag (E64)
Get medical attention for eyes
Personnel Required:
Aircraft Powerplant Repairer
NOTE
Look for accumulations of dirt conforming
to contour of air inlet Buildup of foreign
matter may be difficult to detect because of
the windswept contour it assumes
1. Wear gloves (E24) Clean visible portion of air
inlet housing assembly (1)with wiping rag
(E64) dampened in dry cleaning solvent (E19)
FOLLOW-ON MAINTENANCE
Inspect Air Inlet Housing Assembly (Task 2-50)
END OF TASK