INSTALL OUTPUT SHAFT SEAL AND HOUSING ASSEMBLY (Cont)
Up
TM-1-2840-252-23-2 Engine Gas Turbine Model T55-L-714 Manual
Next
INSTALL OUTPUT SHAFT SEAL AND HOUSING ASSEMBLY (Cont)

TM 1-2840-252-23-2
2-43
INSTALL OUTPUT SHAFT SEAL AND HOUSING ASSEMBLY (Continued)
2-43
b. Find depth measured in shim selection table
SHIM SELECTION TABLE
Read across to find shim thickness required.
Depth
Shim Thickness
Measured
Required
Inch
Inch
0.510
0.038
0.511
0.036
0.512
0.036
0.513
0.034
0.514
0.034
0.515
0.032
0.516
0.032
0.517
0.030
0.518
0.030
0.519
0.028
0.520
0.028
0.521
0.026
0.522
0.026
0.523
0.024
0.524
0.024
0.525
0.022
0.526
0.022
0.527
0.020
0.528
0.020
0.529
0.018
0.530
0.018
0.531
0.016
0.532
0.016
0.533
0.014
0.534
0.014
0.535
0.012
0.536
0.012
0.537
0.010
0.538
0.010
0.539
0.008
0.540
0.008
2. Prepare shim (4)as follows
a. Peel off layers (5) as required to obtain shim
thickness required.
b. Measure thickness of shim (4) and check against
shim selection table Use outside micrometer caliper.
INSPECT
GO TO NEXT PAGE
2-340