INSPECT OUPUT SHAFT SEAL AND HOUSING ASSEMBLYNG (Cont)
Up
TM-1-2840-252-23-2 Engine Gas Turbine Model T55-L-714 Manual
Next
INSPECT OUPUT SHAFT SEAL AND HOUSING ASSEMBLYNG (Cont)

TM 1-2840-252-23-2
2-42
REPAIR OUTPUT S AFT SEAL AND HOUSING ASSEMBLY (Continued)
H
2-42
d. Clean housing (5)as follows
WARNING
Dry cleaning solvent (E19) is flammable
and toxic. It can irritate skin and cause
burns. Use only in well-ventilated area,
away from heat and open flame. In case
of contact, immediately flush skin or
eyes with water for at least 15 minutes.
Get medical attention for eyes.
(1) Wear gloves (E24) Immerse and agitate in dry
cleaning solvent (E19) Use brush in seven
grooves (9)
(2) Wipe dry using clean, dry, lint-free cloth (E30)
WARNING
When using compressed air for cleaning,
use approved protective equipment for
eyes and face. Do not use more than 30
psig air pressure. Do not direct air
toward  yourself  or  another  person.
Failure to comply could result in injury
to eyes or skin In case of injury, get
medical attention.
(3) Wear goggles. Blow dry seven grooves (9)
and 16 air-bleed holes (10).